Function Description
① This temperature controller has soft start mode, manual mode and automatic mode functions. The soft start mode is the preheating and dehumidification function, which prevents damage to the heater due to mold moisture, thereby extending the service life of the hot runner.
② Thermocouple type J or K is adjustable; temperature unit ℃ or ℉ is adjustable and displayed in the PV window. Temperature setting range: 34-534℃
③ Input voltage: 220VAC±10% 50—60Hz or 110VAC±10% 50—60Hz optional.
④ Multiple alarm and protection functions: Low temperature alarm, high temperature alarm, temperature sensor wire break alarm, temperature sensor wire reverse connection alarm, hot runner leakage protection alarm.
Technical Parameter Table Function Parameter Setting Table
Item | Code | Description | Factory Setting | ||
Input Voltage | 85V—250VAC | P01 | Temperature unit setting: Can be set to ℃ or ℉ and displayed in SV display window | Factory set to ℃ | |
Input Frequency | 50—60HZ | ||||
Operating Temperature | -10℃—55℃ | P02 | Alarm on/off setting: Set to ON to activate alarm function, set to OFF to cancel alarm function | Factory set to ON | |
Storage Temperature | -20℃—70℃ | ||||
Fuse Specification | 15A 250V ø6mm×30mm, 1‰sec | P03 | Control mode selection: PID control mode or F2y control mode | Factory set to PID mode | |
Temperature Sensor Type (Thermocouple Type) | K, J | ||||
Temperature Setting Range | 40℃—540℃ | P04 | Low temperature time setting: Setting range 0—255S | Factory set to 240S | |
Sampling Speed | 0.1S | ||||
Temperature Measurement Accuracy | ±0.1℃ | P05 | High temperature time setting: Setting range 0—80S | Factory set to 15S | |
Temperature Control Accuracy | ±1℃ | ||||
Output Voltage | 0—220V | P06 | Sensor type selection: K type or J type adjustable | Set according to customer requirements | |
Maximum Output Power | 3.6KW | ||||
Temperature Unit | ℃、℉ | P07 | Key on/lock selection: "uLc" for key on (usable); "Loc" for key locked (unusable) | Factory set to "uLc" |