Function Description
① This temperature controller has soft start mode, manual mode and automatic mode functions. The soft start mode is the preheating and dehumidification function, which prevents damage to the heater due to mold moisture, thereby extending the service life of the hot runner.   
② Thermocouple type J or K is adjustable; temperature unit ℃ or ℉ is adjustable and displayed in the PV window. Temperature setting range: 34-534℃
③ Input voltage: 220VAC±10% 50—60Hz or 110VAC±10% 50—60Hz optional.
④ Multiple alarm and protection functions: Low temperature alarm, high temperature alarm, temperature sensor wire break alarm, temperature sensor wire reverse connection alarm, hot runner leakage protection alarm.



Technical Parameter Table                                              Function Parameter Setting Table

Item



Code

Description

Factory Setting

Input Voltage

85V—250VAC

P01

Temperature unit setting: Can be set to ℃ or ℉ and displayed in SV display window

Factory set to ℃

Input Frequency

50—60HZ

Operating Temperature

-10℃—55℃

P02

Alarm on/off setting: Set to ON to activate alarm function, set to OFF to cancel alarm function

Factory set to ON

Storage Temperature

-20℃—70℃

Fuse Specification

15A 250V ø6mm×30mm, 1‰sec

P03

Control mode selection: PID control mode or F2y control mode

Factory set to PID mode

Temperature Sensor Type (Thermocouple Type)

K, J

Temperature Setting Range

40℃—540℃

P04

Low temperature time setting: Setting range 0—255S

Factory set to 240S

Sampling Speed

0.1S

Temperature Measurement Accuracy

±0.1℃


P05

High temperature time setting: Setting range 0—80S

Factory set to 15S

Temperature Control Accuracy

±1℃

Output Voltage

0—220V

P06

Sensor type selection: K type or J type adjustable

Set according to customer requirements

Maximum Output Power

3.6KW

Temperature Unit

℃、℉

P07

Key on/lock selection: "uLc" for key on (usable); "Loc" for key locked (unusable)

Factory set to "uLc"