The YK-Z temperature controller adopts microcomputer processing chip for soft start, so it can control the temperature more accurately. Especially for multi-point temperature control, it can greatly reduce the cost. The number of segments ranges from a minimum of 4 to a maximum of 128.

The YK-Z temperature controller adopts PIDD or PID control mode, either of which can be selected. PIDD is an internationally leading temperature control technology that can not only control temperature accurately but also extend the service life of the heater by 30%. Temperature unit (℃ or ℉) and thermocouple model (Type J or K) are adjustable.

Synchronous heating function: The temperature controller automatically adjusts the output power to make the temperature of the hot runner nozzle and manifold reach the set temperature at the same time. After the temperature rises to the set value, the controller will give an alarm prompt "Temperature Rise OK", and then production can start to avoid plastic burning.

Applicable power supply voltage: Three-phase 380V or three-phase 200V

Main Features:

1. Integration: The temperature controller and sequence controller are integrated into one body, with small size and multiple control points. The temperature controller can have up to 128 temperature control points, and the sequence controller can control up to 12 points.

2. Unique design, beautiful and practical: The color screen display is like a small laptop computer, which can be flipped open or closed to avoid collision damage.

3. Convenient and quick to use: Temperatures can be set all at once or in segments; temperature units or thermocouple models can be set all at once;

4. Mold parameter storage function: Can store the names and parameters of 10 sets of mold hot runners for easy copy and use in the next production. 

5. Alarm content storage function for checking and troubleshooting alarm causes. 

6. Easy maintenance: Temperature control cards are pluggable; the display is connected to the temperature controller and other control boards via connectors, making maintenance convenient. When the temperature control cabinet fails, there is no need to send the entire cabinet back to the manufacturer, only the temperature control card, display or other control boards need to be sent.

7. High intelligence: Accurate temperature measurement, stable temperature control, synchronous heating function, alarm reminder when the set temperature is reached to avoid raw material burning.

8. Multiple alarm protection functions, good stability, low failure rate and long service life.

 

Protection and Alarm Functions

1. Thermocouple break alarm

2. Thermocouple reverse connection alarm

3. Fuse break alarm

4. Heater break alarm

5. Heater power line break alarm

6. Thyristor short circuit alarm

7. Over-temperature alarm

8. System fault alarm

9. A special protection device is provided when the neutral wire or live wire is missing in the three-phase four-wire power supply or the neutral wire and live wire are connected in the wrong position, which will automatically protect and not damage any accessories.

10. Alarm prompt when temperature rises to the set temperature



Alarm Information Prompt

Alarm Information

Information Content

SENSOR OPEN ERROR

Temperature sensor wire break

SENSOR REVERSE ERROR

Temperature sensor wire reverse connection

FUSE OPEN ERROR

Fuse break

POWER/HEATER/TRIAC

Power line break/Heater break/Thyristor short circuit

OVER TEMP (SET+30℃)

Over-temperature alarm

CONTROLLER COM ERROR

System fault

TEMP-UP... OK

Alarm prompt when temperature rises to the set temperature





Technical Parameter Description

Item

Parameter

Power Supply Voltage

200V/60Hz (3P+E) 380V/60Hz (3P+N+E)

Power Supply Frequency

50—60HZ

Operating Temperature

-20—60℃

Storage Temperature

-30—70℃

Fuse Specification

15A, 6×30mm

Thermocouple

Type J, K adjustable

Temperature Setting Range

0—499℃

Sampling Speed

0.1s

Temperature Measurement Accuracy

0.5℃

Temperature Control Accuracy

±1℃

Control Mode

PID

Output Power

0—3.6KW

Over-high Temperature Alarm Upper Limit

30℃

Over-low Temperature Alarm Lower Limit

30℃