Function Description
1. One controller controls 2 heating zones, reducing chassis volume and saving space.
2. Automatic ambient temperature linear compensation, making the controller temperature value more accurate
3. Automatic cold junction compensation of thermocouple, avoiding relative error caused by ambient temperature change
4. Alarm protection functions:
Hot runner power cord or heater short circuit alarm
Hot runner temperature sensor wire short circuit alarm
Hot runner heater or power cord open circuit alarm
Hot runner temperature sensor wire break alarm
Hot runner power cord and temperature sensor wire misconnection alarm
Temperature sensor wire positive and negative reverse connection alarm
High temperature alarm
Low temperature alarm
SCR damage alarm
Fuse damage alarm
Alarm Information Comparison Table Technical Parameter Table Function Parameter Factory Settings
Fault Information | Fault Cause | Item | Parameter | Item | |||
| Temperature Sensor Wire Open Circuit | Input Voltage | 185-250VAC | Thermocouple Type | Type J | ||
Power Frequency | 50-60HZ | Over Temperature Alarm Upper Limit | 30℃ | ||||
| Temperature Sensor Wire Reverse Connection | Operating Temperature | -20—60℃ | Low Temperature Alarm Lower Limit | -30℃ | ||
Storage Temperature | -30—70℃ | Temperature Unit | Celsius ℃ | ||||
| Temperature Sensor Wire Short Circuit | Fuse | 16A 10×38mm | Control Mode | PIDD | ||
Thermocouple | J, K adjustable | Soft Start Mode | ON (Enabled) | ||||
| Heater or Connecting Wire Open Circuit | Temperature Setting Range | 45—537℃ | ||||
Sampling Speed | 0.1S | ||||||
| Heater or Connecting Wire Short Circuit | Temperature Measurement Accuracy | 0.1℃ | ||||
Temperature Control Accuracy | ±0.5℃ | ||||||
| Fuse Break | Control Mode | PIDD or PID | ||||
Output Power | 0—3.6KW | ||||||
| SCR Short Circuit Alarm |