yk-z-15A

YK-Z Alarm Function
1. Thermocouple disconnection alarm
2. Thermocouple reverse connection alarm
3. Fuse disconnection alarm
4. Heater disconnection alarm
5. Alarm for power line disconnection of the heater
6. Silicone controlled short circuit alarm
7. Excess temperature alarm
8. Alarm of system failure
9. As for three-phase four-wire power supply, if there is no null line or power wire or the null line and power wire are connected incorrectly, there will be dedicated protective device for such situation. That is protection will be provided automatically, which protect the components from being damaged.
10. When the temperature increases to the set temperature, there will be alarm.
Alarm information
|
Alarm |
Alarm For |
|
SENSOR OPEN ERROR |
The temperature sensor is disconnected. |
|
SENSOR REVERSE ERROR |
The temperature sensor is in reverse connection. |
|
FUSE OPEN ERROR |
The fuse is disconnected. |
|
POWER/HEATER/TRIAC |
The power supply is disconnected / the heater is disconnected / the silicone controlled is in short circuit. |
|
OVER TEMP (SET+30℃) |
Excess temperature |
|
CONTROLLER COM ERROR |
System is in failure |
|
TEMP-UP... OK |
The temperature is increased to the set temperature |
Technical Parameter
|
Item |
Parameter |
|
Supply voltage |
200V/60Hz (3P+E) 380V/60Hz (3P+N+E) |
|
Supply frequency |
50—60HZ |
|
Operation temperature |
-20—60℃ |
|
Storage temperature |
-30—70℃ |
|
Fuse specification |
15A,6×30mm |
|
Thermocouple |
J, K adjustable |
|
Range of set temperature |
0—499℃ |
|
Sampling velocity |
0.1s |
|
Temperature measurement accuracy |
0.5℃ |
|
Temperature control accuracy |
±1℃ |
|
Control mode |
PID |
|
Output power |
0—3.6KW |
|
Upper limit of ultra-temperature alarm |
30℃ |
|
Lower limit of ultralow temperature alarm |