Yk-E-15A instruction manual
Yk-E-15A
Function1. One controller controls two heating zones, reducing the size of the chassis and saving space.
2. Automatic environmental temperature linear compensation, so that the controller's temperature value is more accurate.
3. Automatic cold junction compensation for thermocouples to avoid relative errors due to ambient temperature changes.
4. Alarm protection function:
Short circuit alarm of hot runner power line or heater
Hot runner temperature line short-circuit alarm
The broken circuit alarm of hot runner power line or heater
Temperature cable disconnection alarm of hot runner
Misconnection alarm of hot runner power line and thermocouple
Reverse connection alarm of wire positive and negative polarity
High temperature alarm
Low temperature alarm
SCR damage alarm
Fuse damage alarm
Alarm information table Technical parameter table Function parameter
factory setting
|
|
Thermocouple broken |
|
Voltage |
185-250VAC |
|
Type of thermocouple |
type J |
|
Power frequency |
50-60HZ |
High temperature alarm upper limit |
30℃ |
||||
|
|
Reverse connection of thermocouple |
Operating temperature |
-20—60℃ |
Low temperature alarm lower limit |
-30℃ |
||
|
Storage temperature |
-30—70℃ |
Temperature unit |
℃ |
||||
|
|
The broke circuit of thermocouple |
Fuse specification |
16A10×38mm |
Control mode |
PIDD |
||
|
Thermocouple |
J/K adjustable |
Soft-start mode |
ON |
||||
|
|
Heater or connection line broken |
Temperature range |
45—537℃ |
||||
|
Sampling speed |
0.1S |
||||||
|
|
The broken circuit of heater or connection line |
Temperature measurement accuracy |
0.1℃ |
||||
|
Temperature controlling accuracy |
±0.5℃ |
||||||
|
|
Fuse damage |
Control mode |
PIDD/PID |
||||
|
Output power |
0—3.6KW |
||||||
|
|
SCR damage alarm
|