TMS-001 instruction manual
Function:
1. Operating voltage is 200VA-240VA. Frequency is 50HZ-60HZ.
2. Control mode: Manual control mode and automatic control mode are available.
3. The period of controlling time can be divided into two parts, that is T1 and T2. T1 is the time of opening the gate, and T2 is the time of delaying opening gate.
4. The range of adjusting time: 0-999.9s
5. Input voltage: 220VAC、110VAC、24VDC (Injection machine jetting output )or switch signals are available. Signal line doesn't divide the positive and negative line or zero line connected arbitrarily.
6. Output controlling voltage: 220VAC、110VAC、24VDC is available.
7. Output controlling: Gas valve or oil valve.
Technical parameter table
| Project | |
| Power voltage | 185V-250VAC |
| Voltage frequency | 50HZ-60HZ |
| Operating temperature | -20℃-60℃ |
| Storage temperature | -30℃-70℃ |
| Fuse specification | 3A, 6mm*30mm,1‰ sec |
| Input signal | 24VDC or switch signal |
| Output voltage | 12VDC, 24VDC, 110VAC, 220VAC |
| Output controlling | gas valve or oil valve |
| Controlling time | T1 time of opening the gate, T2 time of delaying opening the gate |
| Time precision | 0.1s |